Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sci Rep ; 12(1): 10970, 2022 06 29.
Artículo en Inglés | MEDLINE | ID: covidwho-1908293

RESUMEN

Pharmaceutical wastewater contamination via azithromycin antibiotic and the continuous emergence of some strains of bacteria, cancer, and the Covid-19 virus. Azithromycin wastewater treatment using the biosynthesized Hematite nanoparticles (α-HNPs) and the biocompatible activities of the resulted nanosystem were reported. Biofabrication of α-HNPs using Echinacea purpurea liquid extract as a previously reported approach was implemented. An evaluation of the adsorption technique via the biofabricated α-HNPs for the removal of the Azr drug contaminant from the pharmaceutical wastewater was conducted. Adsorption isotherm, kinetics, and thermodynamic parameters of the Azr on the α-HNPs surface have been investigated as a batch mode of equilibrium experiments. Antibacterial, anticancer, and antiviral activities were conducted as Azr@α-HNPs. The optimum conditions for the adsorption study were conducted as solution pH = 10, 150 mg dose of α-HNPs, and Azr concentration 400 mg/L at 293 K. The most fitted isothermal model was described according to the Langmuir model at adsorption capacity 114.05 mg/g in a pseudo-second-order kinetic mechanistic at R2 0.9999. Thermodynamic study manifested that the adsorption behavior is a spontaneous endothermic chemisorption process. Subsequently, studying the biocompatible applications of the Azr@α-HNPs. Azr@α-HNPs antibacterial activity revealed a synergistic effect in the case of Gram-positive more than Gram-negative bacteria. IC50 of Azr@α-HNPs cytotoxicity against MCF7, HepG2, and HCT116 cell lines was investigated and it was found to be 78.1, 81.7, and 93.4 µg/mL respectively. As the first investigation of the antiviral use of Azr@α-HNPs against SARS-CoV-2, it was achieved a safety therapeutic index equal to 25.4 revealing a promising antiviral activity. An admirable impact of the use of the biosynthesized α-HNPs and its removal nanosystem product Azr@α-HNPs was manifested and it may be used soon as a platform of the drug delivery nanosystem for the biomedical applications.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Contaminantes Químicos del Agua , Adsorción , Antibacterianos/farmacología , Antivirales , Azitromicina/farmacología , Humanos , Concentración de Iones de Hidrógeno , Cinética , Nanopartículas Magnéticas de Óxido de Hierro , Preparaciones Farmacéuticas , SARS-CoV-2 , Termodinámica , Aguas Residuales , Contaminantes Químicos del Agua/análisis
2.
Int J Mol Sci ; 22(16)2021 Aug 13.
Artículo en Inglés | MEDLINE | ID: covidwho-1662675

RESUMEN

Iron oxide nanoparticles and single domain antibodies from camelids (VHHs) have been increasingly recognized for their potential uses for medical diagnosis and treatment. However, there have been relatively few detailed characterizations of their pharmacokinetics (PK). The aim of this study was to develop imaging methods and pharmacokinetic models to aid the future development of a novel family of brain MRI molecular contrast agents. An efficient near-infrared (NIR) imaging method was established to monitor VHH and VHH conjugated nanoparticle kinetics in mice using a hybrid approach: kinetics in blood were assessed by direct sampling, and kinetics in kidney, liver, and brain were assessed by serial in vivo NIR imaging. These studies were performed under "basal" circumstances in which the VHH constructs and VHH-conjugated nanoparticles do not substantially interact with targets nor cross the blood brain barrier. Using this approach, we constructed a five-compartment PK model that fits the data well for single VHHs, engineered VHH trimers, and iron oxide nanoparticles conjugated to VHH trimers. The establishment of the feasibility of these methods lays a foundation for future PK studies of candidate brain MRI molecular contrast agents.


Asunto(s)
Camélidos del Nuevo Mundo/inmunología , Riñón/química , Hígado/química , Nanopartículas Magnéticas de Óxido de Hierro/química , Anticuerpos de Dominio Único/administración & dosificación , Administración Intravenosa , Animales , Química Encefálica , Femenino , Fluorometría , Humanos , Ratones , Modelos Teóricos , Tamaño de la Partícula , Anticuerpos de Dominio Único/sangre , Anticuerpos de Dominio Único/química
3.
J Nanobiotechnology ; 19(1): 301, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1448238

RESUMEN

BACKGROUND: In the past decades, different diseases and viruses, such as Ebola, MERS and COVID-19, impacted the human society and caused huge cost in different fields. With the increasing threat from the new or unknown diseases, the demand of rapid and sensitive assay method is more and more urgent. RESULTS: In this work, we developed a magneto-optical biochip based on the Cotton-Mouton effect of γ-Fe2O3@Au core/shell magnetic nanoparticles. We performed a proof-of-concept experiment for the detection of the spike glycoprotein S of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The assay was achieved by measuring the magneto-optical Cotton-Mouton effect of the biochip. This magneto-optical biochip can not only be used to detect SARS-CoV-2 but also can be easily modified for other diseases assay. CONCLUSION: The assay process is simple and the whole testing time takes only 50 min including 3 min for the CM rotation measurement. The detection limit of our method for the spike glycoprotein S of SARS-CoV-2 is estimated as low as 0.27 ng/mL (3.4 pM).


Asunto(s)
Anticuerpos Antivirales/inmunología , Prueba de COVID-19/métodos , COVID-19/diagnóstico , Nanopartículas Magnéticas de Óxido de Hierro/química , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , COVID-19/virología , Compuestos Férricos/química , Oro/química , Humanos , Inmunoensayo , Límite de Detección , Prueba de Estudio Conceptual , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad
4.
Mikrochim Acta ; 188(10): 335, 2021 Sep 09.
Artículo en Inglés | MEDLINE | ID: covidwho-1411927

RESUMEN

A practical colorimetric assay was developed for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). For this purpose, magnetic γ Fe2O3 nanoparticles were synthesized and used as a peroxidase-like mimic activity molecule. In the presence of γ Fe2O3 nanoparticles, the color change of H2O2 included 3,3',5,5'-tetramethylbenzidine was monitored at the wavelength of 654 nm when spike protein interacted with angiotensin-converting enzyme 2 receptor. This oxidation-reduction reaction was examined both spectroscopically and by using electrochemical techniques. The experimental parameters were optimized and the analytical characteristics investigated. The developed assay was applied to real SARS-CoV-2 samples, and very good results that were in accordance with the real time polymerase chain reaction were obtained.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Colorimetría/métodos , Nanopartículas Magnéticas de Óxido de Hierro/química , SARS-CoV-2/química , Glicoproteína de la Espiga del Coronavirus/química , Enzima Convertidora de Angiotensina 2/metabolismo , Bencidinas/química , Técnicas Biosensibles/métodos , Prueba de COVID-19/instrumentación , Catálisis , Compuestos Cromogénicos/química , Cisteína/química , Humanos , Peróxido de Hidrógeno/química , Límite de Detección , Nasofaringe/virología , Orofaringe/virología , Oxidación-Reducción , Peroxidasa/química , Glicoproteína de la Espiga del Coronavirus/metabolismo
5.
Biosensors (Basel) ; 11(7)2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1323109

RESUMEN

The feasibility of using Superparamagnetic Iron Oxide Nanoparticles (SPIONs) encapsulated by lipid-polymer nanoparticles as labels in lateral flow immunoassays (LFIA) was studied. First, nanoparticles were synthesized with average diameters between 4 and 7 (nm) through precipitation in W/O microemulsion and further encapsulated using lipid-polymer nanoparticles. Systems formulated were characterized in terms of size and shape by DLS (Nanozetasizer from Malvern) and TEM. After encapsulation, the average size was around (≈20 and 50 nm). These controlled size agglomerates were tested as labels with a model system based on the biotin-neutravidin interaction. For this purpose, the encapsulated nanoparticles were conjugated to neutravidin using the carbodiimide chemistry, and the LFIA was carried out with a biotin test line. The encapsulated SPIONs showed that they could be promising candidates as labels in LFIA test. They would be useful for immunomagnetic separations, that could improve the limits of detection by means of preconcentration.


Asunto(s)
Inmunoensayo , Nanopartículas Magnéticas de Óxido de Hierro , Técnicas Biosensibles , Lípidos , Polímeros/química
6.
Talanta ; 227: 122207, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1078201

RESUMEN

Since December 2019, Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has caused millions of deaths and seriously threatened the safety of human life; indeed, this situation is worsening and many people are infected with the new coronavirus every day. Therefore, it is very important to understand patients' degree of infection and infection history through antibody testing. Such information is useful also for the government and hospitals to formulate reasonable prevention policies and treatment plans. In this paper, we develop a lateral flow immunoassay (LFIA) method based on superparamagnetic nanoparticles (SMNPs) and a giant magnetoresistance (GMR) sensing system for the simultaneously quantitative detection of anti-SARS-CoV-2 immunoglobulin M (IgM) and G (IgG). A simple and time-effective co-precipitation method was utilized to prepare the SMNPs, which have good dispersibility and magnetic property, with an average diameter of 68 nm. The Internet of Medical Things-supported GMR could transmit medical data to a smartphone through the Bluetooth protocol, making patient information available for medical staff. The proposed GMR system, based on SMNP-supported LFIA, has an outstanding advantage in cost-effectiveness and time-efficiency, and is easy to operate. We believe that the suggested GMR based LFIA system will be very useful for medical staff to analyze and to preserve as a record of infection in COVID-19 patients.


Asunto(s)
Anticuerpos Antivirales/sangre , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2/inmunología , Animales , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Antivirales/inmunología , Bovinos , Teléfono Celular , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Internet de las Cosas , Límite de Detección , Nanopartículas Magnéticas de Óxido de Hierro/química , Fenómenos Magnéticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA